S1012-T
|
Hydraulic, single acting
chevron sealing set, machined surface design for heavy industry hydraulics.
|
-30 °C |
100°C |
0.5m/s |
500 bar |
S10-A
Ecotal/
Ecomid |
S11-T
Ecotal/
Ecomid |
S12-T
Ecopur
H-Ecopur
T-Ecopur
S-Ecopur
G-Ecopur |
Ecoflon2 |
Ecoflon2 |
Ecorub1
Ecorub2
Ecorub3
EcorubH |
|
-20 °C |
100°C |
0.5 m/s |
500 bar |
-40 °C |
100°C |
0.5 m/s |
500 bar |
-20 °C |
100°C |
0.7 m/s |
500 bar |
-30 °C |
100°C |
0.5 m/s |
500 bar |
-30 °C |
100°C |
0.5 m/s |
250 bar |
-20 °C |
200 °C |
0.5 m/s |
250 bar |
-50 °C |
-150 °C |
0.5 m/s |
250 bar |
-25 °C |
-150 °C |
0.5 m/s |
250 bar |
|
|
|
|
|
|
|
|
|
|
S1315-T
|
Hydraulic, single acting
chevron sealing set, design with flexible sealing lips, good sealing ability in higher pressure range. for heavy industry hydraulics, water-hydraulic systems.
|
-30 °C |
100°C |
0.5m/s |
500 bar |
S13-T
Ecotal/
Ecomid |
S14-T
Ecotal/
Ecomid |
S15-T
Ecopur
H-Ecopur
T-Ecopur
S-Ecopur
G-Ecopur |
-20 °C |
100°C |
0.5 m/s |
500 bar |
-40 °C |
100°C |
0.5 m/s |
500 bar |
-20 °C |
100°C |
0.7 m/s |
500 bar |
-30 °C |
100°C |
0.5 m/s |
500 bar |
|
|
|
|
|
|
|
|
|
|
S16-A
|
Hydraulic/pneumatic, single acting
simple hat seal, usually fixed in housing with clamp flange. mainly used for replacement in old hydraulic and pneumatic cylinders or for secondary applications.
|
-30 °C |
110 °C |
0,5 m/s |
160 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,5 m/s |
160 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,7 m/s |
160 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,5 m/s |
160 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,5 m/s |
160 bar |
G-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 1 |
|
-25 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
|
-20 °C |
200 °C |
0,5 m/s |
160 bar |
ECORUBBER 2 |
|
-50 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
|
|
|
|
|
|
|
|
|
|
|
S16-B
|
Hydraulic/pneumatic, single acting
simple hut seal, usually fixed in housing with clamp flange. mainly used for replacement in old hydraulic and pneumatic cylinders or for secondary applications.
|
-30 °C |
110 °C |
0,5 m/s |
160 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,5 m/s |
160 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,7 m/s |
160 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,5 m/s |
160 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,5 m/s |
160 bar |
G-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 1 |
|
-25 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
|
-20 °C |
200 °C |
0,5 m/s |
160 bar |
ECORUBBER 2 |
|
-50 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
|
|
|
|
|
|
|
|
|
Go Top |
|
S17-P
|
Hydraulic, single acting
asymmetric rod seal with additional sealing - respectively stabilizing lip. interference fit on outside diameter maintains stable fit in the housing. design mainly used for telescopic cylinders, mobile hydraulic or for special housing dimension.
|
-30 °C |
110 °C |
0,5 m/s |
400bar |
ECOPUR |
|
-20 °C |
110 °C |
0,5 m/s |
400bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,7 m/s |
400bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,5 m/s |
400bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,5 m/s |
400bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S17-R
|
Hydraulic, single acting
as profile S17-P, but more adaption possibilities to diverse temperatures and media by selection of suitable seal material.
|
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 1 |
|
-25 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
|
-20 °C |
200 °C |
0,5 m/s |
160 bar |
ECORUBBER 2 |
|
-50 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
|
|
|
|
|
|
|
|
|
|
|
S18-P
|
Hydraulic, single acting
asymmetric rod seal as S17-P, but due to design with active backring suitable for larger extrusion gaps or higher pressure.
|
|
|
|
|
Seal Part |
Back up ring |
-30 °C |
100 °C |
0,5 m/s |
600 bar |
ECOPUR |
ECOMID |
-20 °C |
100 °C |
0,5 m/s |
600 bar |
H-ECOPUR |
ECOTAL |
-20 °C |
100 °C |
0,7 m/s |
600 bar |
S-ECOPUR |
ECOMID |
-40 °C |
100 °C |
0,5 m/s |
600 bar |
T-ECOPUR |
ECOMID |
-30 °C |
100 °C |
0,5 m/s |
600 bar |
G-ECOPUR |
ECOTAL |
|
|
|
|
|
|
|
|
|
|
S18-R
|
Hydraulic, single acting
asymmetric rod seal with additional sealing - respectively stabilizing lip and back ring. good adaption possibilities to diverse temperatures and medias by selection of suitable seal material, due to design with active back ring suitable for larger extrusion gaps or higher pressure.
|
|
|
|
|
Seal Part |
Back up ring |
-30 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER1 |
ECOTAL |
-30 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 1 |
ECOMID |
-20 °C |
200 °C |
0,5 m/s |
250 bar |
ECORUBBER 2 |
ECOFLON 2 |
-50 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOTAL |
-40 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOMID |
-50 °C |
150 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOFLON 2 |
-25 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOTAL |
-25 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOMID |
-25 °C |
150 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOFLON 2 |
|
|
|
|
|
|
|
|
|
|
S19-F
|
PTFE rod seal, single acting
finger spring activated, asymmetrical PTFE rod seal, low friction and good dry running properties, excellent chemical and thermal resistance, mainly used in chemical, pharma and food industry.
|
|
|
|
|
Seal part |
Spring |
-200 °C |
260 °C |
15 m/s |
100 bar |
ECOFLON1 |
1.4310 |
-200 °C |
260 °C |
15 m/s |
160 bar |
ECOFLON 2 |
1.4310 |
-200 °C |
260 °C |
15 m/s |
160 bar |
ECOFLON 3 |
1.4310 |
-200 °C |
80 °C |
15 m/s |
200 bar |
ECOPE |
1.4310 |
|
|
|
|
|
|
|
|
Go Top |
|
S20-R
|
Hydraulic, double acting
space saving, compact rod seal, suitable for standard O-ring housings. advantage compared to O-ring: integrated active backrings for high pressure, design with interference fit on outside diameter maintains non-twisting in dynamic applications.
|
|
|
|
|
Seal part |
Back up
ring |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECORUBBER1 |
Ecotal/ECOMID |
-20 °C |
200 °C |
0,5 m/s |
700 bar |
ECORUBBER 2 |
ECOFLON 2 |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
ECORUBBER-H |
ECOTAL |
-25 °C |
150 °C |
0,5 m/s |
700 bar |
ECORUBBER-H |
ECOPAEK |
|
|
|
|
|
|
|
|
|
|
S21-P
|
Hydraulic, single acting
O-ring activated symmetric rod seal with sharp-edged sealing lips, good sealing effect for high viscosity fluids, not recommended for new designs (profile S03-P prefered)
|
|
|
|
|
Seal part |
O ring |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
ECOPUR |
NBR70 |
-20 °C |
100 °C |
0,5 m/s |
400 bar |
H-ECOPUR |
NBR70 |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
S-ECOPUR |
NBR70 |
-20 °C |
100 °C |
0,7 m/s |
400 bar |
T-ECOPUR |
NBR70 |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
G-ECOPUR |
NBR70 |
|
|
|
|
|
|
|
|
|
|
S22-P
|
Hydraulic, single acting
symmetric rod seal with support ring for simple applications to serve repair purpose, not recommended for new designs (profile S01-P prefered).
|
|
|
|
|
Seal part |
Support ring |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
ECOPUR |
Ecotal /
ECOMID |
-20 °C |
100 °C |
0,5 m/s |
400 bar |
H-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
400 bar |
S-ECOPUR |
|
-40 °C |
100 °C |
0,5 m/s |
400 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
400 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S22-R
|
Hydraulic, single acting
symmetric rod seal as S22-P, but more adaption possibilities to diverse temperatures and media by selection of suitable seal material.
|
|
|
|
|
Seal part |
Support ring |
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER1 |
ECOTAL |
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 1 |
ECOMID |
-20 °C |
200 °C |
0,5 m/s |
160 bar |
ECORUBBER 2 |
ECOFLON 2 |
-50 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
ECOTAL |
-40 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
ECOMID |
-50 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
ECOFLON 2 |
-25 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
ECOTAL |
-25 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
ECOMID |
-25 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
ECOFLON 2 |
|
|
|
|
|
|
|
|
|
|
S24-P
|
Hydraulic, single acting
O-ring activated rod seal with additional stabilizing lips and integrated active back ring for larger extrusion gaps, mainly used in mining industry.
|
|
|
|
|
Seal |
O ring |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
NBR(70 Sh.A) |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
Back ring |
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
Ecotal/Ecomid |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
Go Top |
|
S2527-F
|
PTFE chevron sealing set, single acting
optimized for low pressure, unequal angled chevron design results in good contact pressure even in low pressure range. external spring pretension necessary. mainly used in chemical, pharma and food industry.
|
-200 °C |
260 °C |
1,5 m/s |
100 bar |
S25-F Ecoflon2 |
S26-F Ecoflon1 |
S27-F
Ecoflon2 |
|
|
|
|
|
|
|
|
|
|
S2931-F
|
PTFE chevron sealing set, single acting
optimized for higher pressure, equal angled chevron design suitable for high pressure range. external spring pretension necessary. mainly used in chemical, pharma and food industry.
|
-200 °C |
260 °C |
1,5 m/s |
315 bar |
S29-F Ecoflon2 |
S30-F Ecoflon1 |
S31-F
Ecoflon2 |
|
|
|
|
|
|
|
|
|
|
S32-P
|
Hydraulic, single acting
chevron sealing set, design with extremely flexible sealing lips for difficult operating conditions (bad guiding, large tolerance range). available as total chevron sealing set as well as intermediate chevrons only (in case of metal mal and female adapters).
|
|
|
|
|
Seal |
Collar |
-30 °C |
100 °C |
0,5 m/s |
500 bar |
ECOPUR |
Ecotal/Ecomid |
-20 °C |
100 °C |
0,5 m/s |
500 bar |
H-ECOPUR |
Back ring |
-40 °C |
100 °C |
0,5 m/s |
500 bar |
T-ECOPUR |
Ecotal/Ecomid |
-20 °C |
100 °C |
0,7 m/s |
500 bar |
S-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
500 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S35-P
|
Hydraulic, double acting
compact rod seal with almost no dead spots as required for applications in food and pharma industry, also commonly used as O-ring replacement, because design with interference fit on outside diameter maintains non-twisting in dynamic applications.
|
-30 °C |
110 °C |
0,4 m/s |
400 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,4 m/s |
400 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,5 m/s |
400 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,4 m/s |
400 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,4 m/s |
400 bar |