Rod Seals |
|
S01-P
|
Hydraulic, single acting
asymmetric rod seal for standard applications. interference fit on outside diameter maintains stabile fit in the housing. design provides ultimate sealing effect over a wide temperature range, good backpumping ability and low tendency to "stick-slip". also used as secondary seal in combination with O-ring activated PTFE-seal type S09.
|
-30 °C |
110 °C |
0,5 m/s |
400 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,5 m/s |
400 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,7 m/s |
400 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,5 m/s |
400 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,5 m/s |
400 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S01-R
|
Hydraulic, single acting
as profile S01-P, but more adapation possibilities to diverse temperatures and media by selection of suitable seal material.
|
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 1 |
|
-25 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
|
-20 °C |
200 °C |
0,5 m/s |
160 bar |
ECORUBBER 2 |
|
-50 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
|
-60 °C |
200 °C |
0 m/s |
0 bar |
ECOSIL |
|
|
|
|
|
|
|
|
|
|
|
S02-P
|
Hydraulic, single acting
asymmetric rod seal for standard applications as S01-P, but due to design with active backring suitable for larger extrusion gaps or higher pressure.
S02-P for standard housing design.
|
|
|
|
|
Seal part |
Backup ring |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
Ecotal /
Ecomid |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
|
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
|
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
|
-50 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-40 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S02-PD
|
Hydraulic, single acting
asymmetric rod seal for standard applications as S02-P, but design with triangular backring for short housings.
|
|
|
|
|
Seal part |
Backup ring |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
ECOTAL |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
ECOMID |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
ECOTAL |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
ECOMID |
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
ECOTAL |
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
ECOMID |
-50 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
ECOTAL |
-40 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
ECOMID |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
ECOTAL |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
ECOMID |
|
|
|
|
|
|
|
|
Go Top |
|
S02-R
|
Hydraulic, single acting
as profile S02-P, but more adaption possibilities to diverse temperatures and media by selection of suitable seal material.
S02-R for standard housing design.
|
|
|
|
|
Seal part |
Backup ring |
-30 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 1 |
ECOTAL |
-30 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 1 |
ECOMID |
-20 °C |
200 °C |
0,5 m/s |
250 bar |
ECORUBBER 2 |
ECOFLON 2 |
-50 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOTAL |
-40 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOMID |
-50 °C |
150 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOFLON 2 |
-25 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOTAL |
-25 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOMID |
-25 °C |
150 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOFLON 2 |
|
|
|
|
|
|
|
|
|
|
S02-RD
|
Hydraulic, single acting
asymmetric rod seal for standard applications as S02-R, but design with triangular backring for short housings
|
|
|
|
|
Seal part |
Backup ring |
-30 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 1 |
ECOTAL |
-30 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 1 |
ECOMID |
-20 °C |
200 °C |
0,5 m/s |
250 bar |
ECORUBBER 2 |
ECOFLON 2 |
-50 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOTAL |
-40 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOMID |
-50 °C |
150 °C |
0,5 m/s |
250 bar |
ECORUBBER 3 |
ECOFLON 2 |
-25 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOTAL |
-25 °C |
100 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOMID |
-25 °C |
150 °C |
0,5 m/s |
250 bar |
ECORUBBER-H |
ECOFLON 2 |
|
|
|
|
|
|
|
|
|
|
S03-P
|
Hydraulic, single acting
O-ring activated, asymmetrical rod seal. interference fit on outside diameter maintains stable fit in the housing. design provides ultimate sealing effect. especially suitable for short stroke applications (e.g. spindle seals, coupling actuators...)
|
|
|
|
|
Seal part |
O ring |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
ECOPUR |
NBR70 |
-20 °C |
100 °C |
0,5 m/s |
400 bar |
H-ECOPUR |
NBR70 |
-20 °C |
100 °C |
0,7 m/s |
400 bar |
S-ECOPUR |
NBR70 |
-50 °C |
100 °C |
0,5 m/s |
400 bar |
T-ECOPUR |
NBR70 |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
G-ECOPUR |
NBR70 |
|
|
|
|
|
|
|
|
|
|
S03-F
|
PTFE-rodseal, single acting
O-ring activated, asymmetrical PTFE rod seal, low friction and good dry running properties. good adaption possibilities to diverse temperatures and media by selection of suitable O-ring material, almost no dead spots as required for applications in food and pharma industry.
|
|
|
|
|
Seal part |
O ring |
-20 °C |
200 °C |
1 m/s |
100 bar |
ECOFLON 1 |
FPM75 |
-20 °C |
200 °C |
1 m/s |
160 bar |
ECOFLON 2 |
FPM75 |
-25 °C |
150 °C |
1 m/s |
100 bar |
ECOFLON 1 |
ECORUBBER-H |
-25 °C |
150 °C |
1 m/s |
160 bar |
ECOFLON 2 |
ECORUBBER-H |
-60 °C |
80 °C |
0,5 m/s |
200 bar |
ECOPE |
MVQ70 |
-60 °C |
200 °C |
1 m/s |
100 bar |
ECOFLON 1 |
MVQ70 |
-60 °C |
200 °C |
1 m/s |
160 bar |
ECOFLON 2 |
MVQ70 |
|
|
|
|
|
|
|
|
|
|
S03-S
|
PTFE-rodseal, single acting
helicoil spring activated, asymmetrical PTFE rod seal, low friction and good dry running properties, excellent chemical and thermal resistance, mainly used in chemical, pharma and food industry.
|
|
|
|
|
Seal part |
Spring |
-200 °C |
260 °C |
1 m/s |
100 bar |
ECOFLON 1 |
1.4310 |
-200 °C |
260 °C |
1 m/s |
160 bar |
ECOFLON 2 |
1.4310 |
-200 °C |
80 °C |
1 m/s |
200 bar |
ECOPE |
1.4310 |
|
S04-P
|
Hydraulic, single acting
asymmetrical rod seal for standard applications as S03-P, but due to design with active back-up ring suitable for larger extrusion gaps orhigher pressure.
S04-P for standard housing design.
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
Ecotal / Ecomid |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
O - Ring |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
NBR 70 Sh.A |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S04-PD
|
Hydraulic, single acting
asymmetric rod seal for standard applications as S04-P, but design with triangular backring for short housings
|
|
|
|
|
Seal part |
Backup ring |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
Ecotal / Ecomid |
-30 °C |
100 °C |
0,5 m/s |
700 bar |
ECOPUR |
O - Ring |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
NBR 70 Sh.A |
-20 °C |
100 °C |
0,5 m/s |
700 bar |
H-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
|
-20 °C |
100 °C |
0,7 m/s |
700 bar |
S-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
T-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
-30 °C |
100 °C |
0,5 m/s |
700 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S05-P
|
Pneumatic,Single acting asymmetric rod seal, extremely wear resistant, for use in lubricated or dry pneumatic applications. Special design of sealing lip allows retention of initial lubricating film |
-30 °C |
110°C |
1m/s |
25 bar |
ECOPUR |
|
-20 °C |
110°C |
1m/s |
25 bar |
H-ECOPUR |
|
-20 °C |
110°C |
2m/s |
25 bar |
S-ECOPUR |
|
-50 °C |
110°C |
1m/s |
25 bar |
T-ECOPUR |
|
-50 °C |
110°C |
1m/s |
25 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S05-R
|
Pneumatic,Single acting as profile S05-R, good wear resistance and adaptation possiblities for diverse temperatures and media by selection of suitable seal material. Special design of sealing lip allows retention of initial lubricating film
|
-30 °C |
80 °C |
1m/s |
25 bar |
Ecorubber 1 |
|
-20 °C |
200°C |
1m/s |
25 bar |
Ecorubber 2 |
|
-50 °C |
150 °C |
1m/s |
25 bar |
Ecorubber 3 |
|
-25 °C |
150 °C |
1m/s |
25 bar |
Ecorubber-H |
|
|
|
|
|
|
|
|
|
Go Top |
|
S06-P
|
Hydraulic, single acting
symmetric rod seal for simple standard applications, not recommended for new designs (profile S01-P should be prefered)
|
-30 °C |
110 °C |
0,5 m/s |
400 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,5 m/s |
400 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,7 m/s |
400 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,5 m/s |
400 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,5 m/s |
400 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S06-R
|
Hydraulic, single acting
as profile S06-P, but more adaption possibilities to diverse temperatures and media by selection of suitable seal material.
|
-30 °C |
100 °C |
0,5 m/s |
160 bar |
ECORUBBER 1 |
|
-25 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER-H |
|
-20 °C |
200 °C |
0,5 m/s |
160 bar |
ECORUBBER 2 |
|
-50 °C |
150 °C |
0,5 m/s |
160 bar |
ECORUBBER 3 |
|
-60 °C |
200 °C |
0 m/s |
0 bar |
ECOSIL |
|
|
|
|
|
|
|
|
|
|
|
S07-P
|
Hydraulic, single acting
O-ring activated symmetric rod seal for simple standard applications, not recommended for new designs (profile S03-P prefered)
|
|
|
|
|
Seal part |
O ring |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
ECOPUR |
NBR70 |
-20 °C |
100 °C |
0,5 m/s |
400 bar |
H-ECOPUR |
NBR70 |
-20 °C |
100 °C |
0,7 m/s |
400 bar |
S-ECOPUR |
NBR70 |
-50 °C |
100 °C |
0,5 m/s |
400 bar |
T-ECOPUR |
NBR70 |
-30 °C |
100 °C |
0,5 m/s |
400 bar |
G-ECOPUR |
NBR70 |
|
|
|
|
|
|
|
|
|
|
S08-P
|
Hydraulic, single acting
asymmetric compact rod seal, interference fit on outside diameter maintains stable fit in the housing. compact design mainly used to seal high viscosity fluids or for extreme small housings, not suitable for high speed applications. S08-P compact design, no groove
|
-30 °C |
110 °C |
0,3 m/s |
400 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,3 m/s |
400 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,4 m/s |
400 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,3 m/s |
400 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,3 m/s |
400 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
|
|
S08-PE
|
Hydraulic, single acting
asymmetric compact rod seal, interference fit on outside diameter maintains stable fit in the housing. compact design mainly used to seal high viscosity fluids or for extreme small housings, not suitable for high speed applications. S08-PE with small groove
|
-30 °C |
110 °C |
0,3 m/s |
400 bar |
ECOPUR |
|
-20 °C |
110 °C |
0,3 m/s |
400 bar |
H-ECOPUR |
|
-20 °C |
110 °C |
0,4 m/s |
400 bar |
S-ECOPUR |
|
-50 °C |
110 °C |
0,3 m/s |
400 bar |
T-ECOPUR |
|
-30 °C |
110 °C |
0,3 m/s |
400 bar |
G-ECOPUR |
|
|
|
|
|
|
|
|
|
Go Top |
|
S08-R
|
Hydraulic, single acting
as profile S08-P, but more adaptation possibilities to diverse temperatures and media by selection of suitable seal material.
|
-30 °C |
100°C |
0.3m/s |
160 bar |
ECORUBBER 1 |
|
-20 °C |
200°C |
0.3m/s |
160 bar |
ECORUBBER 2 |
|
-50 °C |
150°C |
0.3m/s |
160 bar |
ECORUBBER 3 |
|
-25 °C |
150°C |
0.3m/s |
160 bar |
ECORUBBER-H |
|
|
|
|
|
|
|
|
|
|
|
S09-E
|
Hydraulic, single acting
O-ring activated asymmetric PTFE rod seal, low friction. in tandem design together with double acting wipers for extreme low or high speed or positioning facilities. as primary seal in combination with secondary SO1-P seal with good resistance to pressure shocks used in mobile hydraulics, machine tools, injection moulding machines, heavy hydraulics.
|
|
|
|
|
Glide ring |
O ring |
-20 °C |
200 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4 Ecope |
FPM75 |
-50 °C |
150 °C |
10 m/s |
400 bar |
|
EPDM70 |
-60 °C |
200 °C |
10 m/s |
400 bar |
|
MVQ70 |
-30 °C |
100 °C |
10 m/s |
400 bar |
|
NBR70 |
|
|
|
|
|
|
|
|
|
|
S09-D
|
Hydraulic, double acting
O-ring activated symmetric PTFE rod seal, low friction. for extreme low or high speed, suitable for positioning functions.
|
|
|
|
|
Glide ring |
O ring |
-30 °C |
100 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4 |
NBR70 |
-20 °C |
200 °C |
10 m/s |
400 bar |
|
FPM/FKM 75 |
-50 °C |
150 °C |
10 m/s |
400 bar |
|
EPDM70 |
-60 °C |
200 °C |
10 m/s |
400 bar |
|
MVQ70 |
-30 °C |
100 °C |
10 m/s |
400 bar |
Ecope |
MVK70/Ecosil |
|
|
|
|
|
|
|
|
|
|
S09-P
|
Hydraulic, single acting
O-ring activated asymmetric PU rod seal with excellent dynamic sealing capacity. used as secondary seal in tandem design (together with primary S09-E seal) to minimize residual oil film. for mobile hydraulics, machine tools, injection moulding machines, heavy hydraulics. |
|
|
|
|
Glide ring |
Energizer |
-30 °C |
100 °C |
1 m/s |
400 bar |
ECOPUR |
NBR70 |
-20 °C |
100 °C |
1 m/s |
400 bar |
H-ECOPUR |
NBR70 |
-20 °C |
100 °C |
1,4 m/s |
400 bar |
S-ECOPUR |
NBR70 |
-50 °C |
100 °C |
1 m/s |
400 bar |
T-ECOPUR |
NBR70 |
-30 °C |
100 °C |
1 m/s |
400 bar |
G-ECOPUR |
NBR70 |
|
|
|
|
|
|
|
|
|
|
S09-ES
|
Hydraulic, single acting
profile ring-activated asymmetric PTFE rod seal, similar to S09-E, but special heavy duty design for heavy industry hydraulics or for special housing dimension.
|
|
|
|
|
Glide ring |
Energizer |
-30 °C |
100 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4 |
ECORUBBER 1 |
-20 °C |
200 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4
|
ECORUBBER 2 |
-50 °C |
150 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4
|
ECORUBBER 3 |
-25 °C |
150 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4
|
ECORUBBER-H |
|
|
|
|
|
|
|
|
|
|
S09-DS
|
Hydraulic, double acting
profile ring-activated symmetric PTFE rod seal, similar to S09-D, but special heavy duty design for heavy industry hydraulics or for special housing dimension.
|
|
|
|
|
Glide ring |
Energizer |
-30 °C |
100 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4 |
ECORUBBER 1 |
-20 °C |
200 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4
|
ECORUBBER 2 |
-50 °C |
150 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4
|
ECORUBBER 3 |
-25 °C |
150 °C |
10 m/s |
400 bar |
Ecoflon-2/3/4
|
ECORUBBER-H |
|
|
|
|
|
|
|
|
|
|
S1012-M
|
Hydraulic, single acting
chevron sealing set, parting surface design for heavy industry hydraulics.
|
-30 °C |
100°C |
0.5m/s |
500 bar |
S10-A
Ecotal/
Ecomid |
S11-M
Ecotal/
Ecomid |
S12-M
Ecopur
H-Ecopur
T-Ecopur
S-Ecopur
G-Ecopur |
Ecoflon2 |
Ecorub1
Ecorub2
Ecorub3
EcorubH |
Ecoflon2 |
|
-20 °C |
100°C |
0.5 m/s |
500 bar |
-40 °C |
100°C |
0.5 m/s |
500 bar |
-20 °C |
100°C |
0.7 m/s |
500 bar |
-30 °C |
100°C |
0.5 m/s |
500 bar |
-30 °C |
100°C |
0.5 m/s |
250 bar |
-20 °C |
200 °C |
0.5 m/s |
250 bar |
-50 °C |
-150 °C |
0.5 m/s |
250 bar |
-25 °C |
-150 °C |
0.5 m/s |
250 bar |
|
|
|
|
|
|
|
|
Go Top |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|