Wipers
Application Profile Description Min temp Max temp Max speed Material

A01-A
A01-A
Hydraulic, single acting
wiper with interference fit on outside diameter, providing a technically accurate closure at the cylinder. wiping edge assures a reliable protection against penetration of dust and dirt whilst allowing backflow of residual oil film. Back support area prevents tilting of wiper.
For housings according ISO 6195-TypA
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material

A01-B
A01-B
Hydraulic, single acting
as profile A01-A, but without back support area. for housings according ISO 6195-TypeA
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material

A02-A
A02-A
Hydraulic, single acting
wiper with interference fit on outside diameter. wiping edge assures a reliable protection against penetration of dust and dirt whilst allowing backflow of residual oil film. back support area prevents tilting of wiper.
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material

A02-B
A02-B
Hydraulic, single acting
as profile A02-A, but without back support area.
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material

A02-I
A02-I
Hydraulic, single acting
as profile A02-A, but without back support area.
special design for housings according ISO 6195-TypC
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
              Go Top
Application Profile Description Min temp Max temp Max speed Material
            Wiping part Housing

A03-A
A03-A
Hydraulic, single acting
wiper with mounting cage for press-fit installation into axially open housings. wiping edge assures a reliable protection against penetration of dust and dirt, the use of plastic mounting cages avoids corrosion in the press-fit.
for housings according ISO 6195-TypB
-30 °C 80 °C 4 m/s ECOPUR ECOTAL
-30 °C 80 °C 4 m/s ECOPUR ECOMID
-20 °C 80 °C 4 m/s H-ECOPUR ECOTAL
-20 °C 80 °C 4 m/s H-ECOPUR ECOMID
-50 °C 80 °C 4 m/s T-ECOPUR ECOTAL
-40 °C 80 °C 4 m/s T-ECOPUR ECOMID
-20 °C 80 °C 5 m/s S-ECOPUR ECOTAL
-20 °C 80 °C 5 m/s S-ECOPUR ECOMID
-30 °C 80 °C 4 m/s G-ECOPUR ECOTAL
-30 °C 80 °C 4 m/s G-ECOPUR ECOMID
-30 °C 80 °C 4 m/s ECORUBBER 1 ECOTAL
-30 °C 80 °C 4 m/s ECORUBBER 2 ECOMID
-25 °C 80 °C 4 m/s ECORUBBER-H ECOTAL
-25 °C 80 °C 4 m/s ECORUBBER-H ECOMID
-20 °C 80 °C 4 m/s ECORUBBER 2 ECOPAEK
-50 °C 80 °C 4 m/s ECORUBBER 3 ECOPAEK
               
Application Profile Description Min temp Max temp Max speed Material

A04-A
A04-A
pneumatic, single acting
wiper with interference fit on outside diameter, providing a technically accurate closure at the cylinder. special design of wiping lip allows retention of initial lubricating film. back support area prevents tilting of wiper.
for housings according ISO 6195-TypA
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material
Resiprocating Application
Screw Type Application
A04-B
A04-B
pneumatic, single acting
as profile A04-A, but without back support area.
for housings according ISO 6195-TypA
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material
Resiprocating Application
Screw Type Application
A05-A
A05-A
pneumatic, single acting
wiper with interference fit on outside diameter. special design of wiping lip allows retention of initial lubricating film. back support area prevents tilting of wiper
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material
Resiprocating Application
Screw Type Application
A05-B
A05-B
pneumatic, single acting
as profile A05-A, but without back support area.
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
              Go Top
Application Profile Description Min temp Max temp Max speed Material
Resiprocating Application
Screw Type Application
A05-I
A05-I
pneumatic, single acting
as profile A05-A, but without back support area. special design for housings according ISO 6195-TypC
-30 °C 110 °C 4 m/s ECOPUR  
-20 °C 110 °C 4 m/s H-ECOPUR  
-50 °C 110 °C 4 m/s T-ECOPUR  
-20 °C 110 °C 5 m/s S-ECOPUR  
-30 °C 110 °C 4 m/s G-ECOPUR  
-30 °C 100 °C 4 m/s ECORUBBER 1  
-25 °C 150 °C 4 m/s ECORUBBER-H  
-20 °C 200 °C 4 m/s ECORUBBER 2  
-50 °C 150 °C 4 m/s ECORUBBER 3  
               
Application Profile Description Min temp Max temp Max speed Material
Resiprocating Application
Screw Type Application
A06-A
A06-A
pneumatic, single acting
wiper with mounting cage for press-fit installation into axially open housings. special design of wiping lip allows retention of initial lubricating film, the use of plastic mounting cages avoids corrosion at the press-fit.
for housings according ISO 6195-TypB
      Wiping part Housing
-30 °C 80 °C 4 m/s ECOPUR ECOTAL
-30 °C 80 °C 4 m/s ECOPUR ECOMID
-20 °C 80 °C 4 m/s H-ECOPUR ECOTAL
-20 °C 80 °C 4 m/s H-ECOPUR ECOMID
-50 °C 80 °C 4 m/s T-ECOPUR ECOTAL
-40 °C 80 °C 4 m/s T-ECOPUR ECOMID
-20 °C 80 °C 5 m/s S-ECOPUR ECOTAL
-20 °C 80 °C 5 m/s S-ECOPUR ECOMID
-30 °C 80 °C 4 m/s G-ECOPUR ECOTAL
-30 °C 80 °C 4 m/s G-ECOPUR ECOMID
-30 °C 80 °C 4 m/s ECORUBBER 1 ECOTAL
-30 °C 80 °C 4 m/s ECORUBBER 2 ECOMID
-25 °C 80 °C 4 m/s ECORUBBER-H ECOTAL
-25 °C 80 °C 4 m/s ECORUBBER-H ECOMID
-20 °C 80 °C 4 m/s ECORUBBER 2 ECOPAEK
-50 °C 80 °C 4 m/s ECORUBBER 3 ECOPAEK
               
Application Profile Description Min temp Max temp Max speed Material
Resiprocating Application
Screw Type Application
A07-A
A07A
Hydraulic, single acting
wiper to fit in angled housings (30°angle). design mainly used in british equipment, in inch as well as metric dimensions.
-30 °C 110 °C 4 m/s 0 bar ECOPUR
-20 °C 110 °C 4 m/s 0 bar H-ECOPUR
-50 °C 110 °C 4 m/s 0 bar T-ECOPUR
-20 °C 110 °C 5 m/s 0 bar S-ECOPUR
-30 °C 110 °C 4 m/s 0 bar G-ECOPUR
-30 °C 100 °C 4 m/s 0 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 0 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 0 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 0 bar ECORUBBER 3
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating Application
Oscillate Type Application
A08-A
Profile
Hydraulic/pneumatic, single acting
wiper usually fixed in housing with clamp flange. mainly used for replacement in old hydraulic and pneumatic cylinders or for secondary applications.
-30 °C 110 °C 4 m/s 0 bar ECOPUR
-20 °C 110 °C 4 m/s 0 bar H-ECOPUR
-50 °C 110 °C 4 m/s 0 bar T-ECOPUR
-20 °C 110 °C 5 m/s 0 bar S-ECOPUR
-30 °C 110 °C 4 m/s 0 bar G-ECOPUR
-30 °C 100 °C 4 m/s 0 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 0 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 0 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 0 bar ECORUBBER 3
              Go Top
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A08-B
Profile
Hydraulic/pneumatic, single acting
wiper usually fixed in housing with clamp flange. mainly used for replacement in old hydraulic and pneumatic cylinders or for secondary applications.
-30 °C 110 °C 4 m/s 0 bar ECOPUR
-20 °C 110 °C 4 m/s 0 bar H-ECOPUR
-50 °C 110 °C 4 m/s 0 bar T-ECOPUR
-20 °C 110 °C 5 m/s 0 bar S-ECOPUR
-30 °C 110 °C 4 m/s 0 bar G-ECOPUR
-30 °C 100 °C 4 m/s 0 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 0 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 0 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 0 bar ECORUBBER 3
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A09-A
Profile
Hydraulic, single acting
wiper with design according to common types used in USA.
for housings according AN 6231, ANSI/B93.35
-30 °C 110 °C 4 m/s 0 bar ECOPUR
-20 °C 110 °C 4 m/s 0 bar H-ECOPUR
-50 °C 110 °C 4 m/s 0 bar T-ECOPUR
-20 °C 110 °C 5 m/s 0 bar S-ECOPUR
-30 °C 110 °C 4 m/s 0 bar G-ECOPUR
-30 °C 100 °C 4 m/s 0 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 0 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 0 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 0 bar ECORUBBER 3
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A10-A
Profile
Hydraulic, single acting
wiper with dimensioning according to common types used in USA. fixed relation between cross-section and height of wiper.
for housings according AN 6231, ANSI/B93.35
-30 °C 110 °C 4 m/s 0 bar ECOPUR
-20 °C 110 °C 4 m/s 0 bar H-ECOPUR
-50 °C 110 °C 4 m/s 0 bar T-ECOPUR
-20 °C 110 °C 5 m/s 0 bar S-ECOPUR
-30 °C 110 °C 4 m/s 0 bar G-ECOPUR
-30 °C 100 °C 4 m/s 0 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 0 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 0 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 0 bar ECORUBBER 3
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A11-A
Profile
Hydraulic/pneumatic, double acting
wiper including additional sealing lip. used in combination with O-ring activated PTFE seals (tandem) to reduce residual oil film. also used as complete solution for pneumatic applications in small diameter range.
max. allow pressure load: 16 bar (230 psi)
-30 °C 110 °C 4 m/s 16 bar ECOPUR
-20 °C 110 °C 4 m/s 16 bar H-ECOPUR
-50 °C 110 °C 4 m/s 16 bar T-ECOPUR
-20 °C 110 °C 5 m/s 16 bar S-ECOPUR
-30 °C 110 °C 4 m/s 16 bar G-ECOPUR
-30 °C 100 °C 4 m/s 16 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 16 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 16 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 16 bar ECORUBBER 3
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A11-1
Profile
Hydraulic/pneumatic, double acting
as profile A11-A, special design for housings according ISO 6195-TypC
-30 °C 110 °C 4 m/s 16 bar ECOPUR
-20 °C 110 °C 4 m/s 16 bar H-ECOPUR
-50 °C 110 °C 4 m/s 16 bar T-ECOPUR
-20 °C 110 °C 5 m/s 16 bar S-ECOPUR
-30 °C 110 °C 4 m/s 16 bar G-ECOPUR
-30 °C 100 °C 4 m/s 16 bar ECORUBBER 1
-25 °C 150 °C 4 m/s 16 bar ECORUBBER-H
-20 °C 200 °C 4 m/s 16 bar ECORUBBER 2
-50 °C 150 °C 4 m/s 16 bar ECORUBBER 3
              Go Top
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A12-A
Profile
Hydraulic, single acting
wiper with secondary lip, the technically accurate closure at the cylinder is providing reliable protection, even for heavy contamination.
-30 °C 110 °C 4 m/s 0 bar ECOPUR
-20 °C 110 °C 4 m/s 0 bar H-ECOPUR
-50 °C 110 °C 4 m/s 0 bar T-ECOPUR
-20 °C 110 °C 5 m/s 0 bar S-ECOPUR
-30 °C 110 °C 4 m/s 0 bar G-ECOPUR
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A13-A
Profile
Hydraulic/pneumatic, single acting
scraper ring, mainly used in combination with wiper A02 or A01. firmly clinging dirt and extremely heavy soiling (mud, tar, ice) is wiped off, following elastomeric wiper is protected from damage. recommended materials provide good dry running properties, high stiffness and breaking strenght.
-50 °C 80 °C 1 m/s 0 bar ECOTAL
-40 °C 80 °C 1 m/s 0 bar ECOMID
-50 °C 260 °C 1 m/s 0 bar ECOPAEK
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A25-F
Profile
Hydraulic/pneumatic, single acting
PTFE-wiper with O-ring as preloading element. PTFE part takes over wiping function, O-ring maintains equal contact pressure. good dry running properties, no "stick-slip". excellent chemical and thermal resistance can be achieved by selection of suitable O-ring material
      Glide ring Energizer
-30 °C 100 °C 10 m/s 0 bar ECOFLON 2
-20 °C 200 °C 10 m/s 0 bar ECOFLON 2
-30 °C 100 °C 10 m/s 0 bar ECOFLON 3
-20 °C 200 °C 10 m/s 0 bar ECOFLON 3
-30 °C 100 °C 10 m/s 0 bar ECOFLON 4
-20 °C 200 °C 10 m/s 0 bar ECOFLON 4
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A26-F
Profile
Hydraulic/pneumatic, double acting
PTFE-double wiper with two O-rings as preloading elements. wiping edge assures a reliable protection against penetration of dust and dirt. additional sealing lip for reduction of residual oil film if used in combination with O-ring activated PTFE seals type S09 (tandem). excellent chemical and thermal resistance can be achieved by selection of suitable O-ring material
      Glide ring Energizer
-30 °C 100 °C 10 m/s 16 bar ECOFLON 2
-20 °C 200 °C 10 m/s 16 bar ECOFLON 2
-30 °C 100 °C 10 m/s 16 bar ECOFLON 3
-20 °C 200 °C 10 m/s 16 bar ECOFLON 3
-30 °C 100 °C 10 m/s 16 bar ECOFLON 4
-20 °C 200 °C 10 m/s 16 bar ECOFLON 4
               
Application Profile Description Min temp Max temp Max speed Material
Reciprocating ApplicationScrewType Application
Oscillate Type Application
A27-F
Profile
Hydraulic/pneumatic, double acting
PTFE-double wiper with O-ring as preloading element. wiping edge assures a reliable protection against penetration of dust and dirt. additional sealing lip for reduction of residual oil film if used in combination with O-ring activated PTFE seals type S09 (tandem). excellent chemical and thermal resistance (depends on O-ring).
      Glide ring Energizer
-30 °C 100 °C 10 m/s 16 bar ECOFLON 2
-20 °C 200 °C 10 m/s 16 bar ECOFLON 2
-30 °C 100 °C 10 m/s 16 bar ECOFLON 3
-20 °C 200 °C 10 m/s 16 bar ECOFLON 3
-30 °C 100 °C 10 m/s 16 bar ECOFLON 4
-20 °C 200 °C 10 m/s 16 bar ECOFLON 4
              Go Top

© 2006. All rights reserved.

website design: Echo Px